Estimated fetal weight (EFW) converts four routine ultrasound measurements into a predicted weight in grams. It's one of the most common numbers reported during a prenatal growth scan, and one of the most commonly misread — a single EFW figure is a statistical estimate with a real margin of error, not a scale reading.

How the Hadlock formula works

The calculator implements the 4-parameter Hadlock regression (Hadlock et al., Am J Obstet Gynecol, 1985), which combines biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL) into a single log-linear equation. AC carries the most weight in the formula because abdominal size is the measurement most sensitive to how well a fetus is growing — it's also the measurement most affected in conditions like macrosomia or growth restriction, which is part of why the formula leans on it so heavily.

Multiple Hadlock formula variants exist depending on which subset of measurements is available (some use only AC and FL, for example). This calculator uses the standard 4-parameter version, since all four measurements are captured on a routine growth ultrasound and it's the version in most common clinical use.

Why the estimate always needs a range, not just a number

Published validation studies put the Hadlock formula's accuracy at roughly ±15–20% (about 2 standard deviations) around the true birth weight, and that error tends to widen further at the extremes — very small or very large fetuses are harder to estimate precisely. A reported EFW of 3,000 g, for example, realistically corresponds to an actual birth weight range spanning several hundred grams in either direction.

This is why the calculator's Margin of Error tab converts the point estimate into a low-high range instead of treating the raw gram figure as exact. Clinically, EFW is used as one input among several — growth-chart percentile trends over multiple scans generally carry more diagnostic weight than any single measurement.

Limits and when to look further

EFW does not replace a formal fetal weight percentile assessment (which requires comparing EFW against a gestational-age-specific growth standard), a biophysical profile, or clinical judgment from the treating provider. It also assumes reasonably accurate, well-obtained measurements — operator technique, fetal position, and maternal body habitus can all introduce additional measurement error beyond the formula's own margin. If a single scan's EFW is unexpectedly high or low, the typical next step is a repeat scan or a formal growth-trend assessment rather than acting on one number in isolation.